Hifu-Finesse
Focused Ultrasound
General technical specifications
| POWER SUPPLY VOLTAGE | 230 Vac 50/60 Hz |
| MAXIMUM POWER | 200 VA |
| SAFETY CLASS AND TYPE OF PART APPLIED | I BF |
| FUSES | 2x F2A – 250V |
| DIMENSIONS | 700(W) x 500(D) x 1300(H) mm |
| WEIGHT | 45 kg |
| ULTRASONIC PULSE DURATION | 100ms |
| LINEAR SCAN | 15 ÷ 40 mm |
| EMISSION STEP | 1 ÷ 5 mm |
| ACTIVATION | “Ready” button and Button |
BODY: dedicated handpiece
Unperforated concave ultrasonic transducer. In the treatment of adipose tissue, the enlargement of the focal area is favourable, so as to partially benefit the overlying tissue. The cooling of the ultrasonic emitter is achieved by means of a hydraulic circuit that allows the water to circulate and actively cool the transducer. | The operational stability of the transducer is safeguarded during the entire treatment. Active cooling helps to increase the emission power of the piezoelectric component; indeed, it is known that an excessive increase in temperature reduces the quality factor of the piezoelectric component during the operating process. The lifespan of the transducer is extended and guaranteed up to 20,000 scan lines, unlike common transducers that have a very limited functioning lifespan. Exposure to thermal stimulus / pulse duration extends up to 200ms. This feature, encourages the diffusion of heat near the point of focus. |
FACE: dedicated handpiece
Ultrasonic transducer with exclusive “Centreless” technology for the facial handpiece. The operational stability of the transducer is safeguarded during the entire treatment. Active cooling helps to increase the emission power of the piezoelectric component; indeed, it is known that an excessive increase in temperature reduces the quality factor of the piezoelectric component during the operating process. The cooling of the ultrasonic emitter is achieved by means of a hydraulic circuit that allows the water to circulate and actively cool the transducer. | Guarantees accuracy of the focal peak intensity with reduced possibility of side effects and better results. In addition, the treatment is much less painful when compared to full transducers. The life span of the transducer is extended and guaranteed up to 20,000 scan lines, unlike common transducers that have very limited functioning lifespan. Exposure to thermal stimulus / reduced pulse duration, starting from 10ms. The feature, further reduces heat diffusion axially and ensures greater circumference in the focal point. |
Technical specifications for Cartridges
1.5mm Cartridge
|
3mm Cartridge
|
4.5mm Cartridge
|
9mm Cartridge
|
Cartuccia 9mm
|

FACE: dedicated handpiece
Technical specifications for Cartridges